CCVLW - NICKEL CADMIUM BATTERY

  • MSDS: CCVLW
  • Manufacturer: BATTERY NETWORK EAST
  • Product Name: NICKEL CADMIUM BATTERY
  • National Stock Number: 6140-00-410-3334
Product Identification

Product ID:NICKEL CADMIUM BATTERY
MSDS Date:03/01/1990
FSC:6140
NIIN:00-410-3334
MSDS Number: CCVLW

Responsible Party
BATTERY NETWORK EAST
50 TANNERY RD UNTI 2
NORTH BRANCH, NJ 08876
US

Emergency Phone: 202-625-3333

Info Phone: 800-221-0019

Cage: BATTR

Contractor
BATTERY NETWORK EAST
5389 NORTH BRANCH, NJ 08876 US

Telephone: 800-221-0019

Cage: BATTR

Ingredients

CADMIUM (SARA 313) (CERCLA) CONTAINING ING 2

CAS: 7440-43-9

RTECS: EU9800000

Fraction By Weight: <26%

OSHA PEL 0.2 MG/M3 DUST; Z-2

ACGIH TLV: 0.01 MG/M3 DUST

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


CADMIUM HYDROXIDE

CAS: 21041-95-2

RTECS: EV1260000

OSHA PEL 0.05 MG CD/M3

ACGIH TLV: 0.05 MG CD/M3


NICKEL (SARA 313) (CERCLA) CONTAINING ING 4

CAS: 7440-02-0

RTECS: QR5950000

Fraction By Weight: <30%

OSHA PEL 1 MG/M3

ACGIH TLV: 1 MG/M3


NICKEL HYDROXIDE (SARA 313) (CERCLA)

CAS: 12054-48-7

RTECS: QR7040000

OSHA PEL 1 MG(NI)/M3

ACGIH TLV: 0.1 MG(NI)/M3

EPA Report Quantity: 10 LBS

DOT Report Quantity: 10 LBS


POTASSIUM HYDROXIDE (CERCLA) (OR ING 6)

CAS: 1310-58-3

RTECS: TT2100000

Fraction By Weight: <4%

OSHA PEL C 2 MG/M3

ACGIH TLV: C 2 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


SODIUM HYDROXIDE

CAS: 1310-73-2

RTECS: WB4900000

OSHA PEL 2 MG/M3

ACGIH TLV: C 2 MG/M3

EPA Report Quantity: 1000 LBS

DOT Report Quantity: 1000 LBS


COBALT HYDROXIDE

CAS: 1307-86-4

RTECS: GG0904000

Fraction By Weight: <1%

OSHA PEL 0.05 MG/M3 (COBALT)

ACGIH TLV: 0.1 MG/M3


LITHIUM HYDROXIDE

CAS: 1310-65-2

RTECS: OJ6307070

Fraction By Weight: 0.02%

OSHA PEL N/K

ACGIH TLV: N/K


LUNGS, NASAL CAVITIES. CADMIUM

RTECS: 9999999ZZ


GROUP 1. NICKEL

RTECS: 9999999ZZ


IARC MONOGRAPHS ON EVAL OF

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:NO
Health Hazards Acute and Chronic:ACUTE:POTASSIUM HYDROXIDE, SODIUM
HYDROXIDE - BURNS TO TISSUE CONTACTED; NICKEL - POSSIBLE CONTACT
DERMATITIS. CHRONIC:CADMIUM - POSSIBLE LUNG OR KIDNEY DAMAGE;
NICKEL - POSSIBLE LUNG DAMAGE.
Explanation of Carcinogenicity:CADMIUM:IARC MONOGRAPHS ON EVAL OF
CARCIN RISK OF CHEMS TO MAN, VOL 58, PG 119, 1993:GROUP 1. NTP 7TH
ANNUAL (SUPDAT)
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:UNKNOWN.

First Aid

First Aid:WASH THOROUGHLY WITH LARGE VOLUME OF WATER IF ELECTROLYTE IS
SPILLED. INHAL:REMOVE TO FRESH AIR; CONT PHYS. EYES:FLUSH WITH
WATER FOR @ LEAST 15 MINS; CONT PHYS. SKIN:WASH W/LARGE VOLUME OF
WATER;MILD ACID MAY BE USED TO NEUTRLIZE. INGEST:CONT PHYS IMMED.

Fire Fighting

Extinguishing Media:SUITABLE FOR SURROUNDING MATERIAL.
Fire Fighting Procedures:USE NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .
Unusual Fire/Explosion Hazard:TOXIC CADMIUM FUMES MAY BE RELEASED
DURING BURNING.

Accidental Release

Spill Release Procedures:FLUSH ELECTROLYTE SPILLS WITH WATER.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:DO NOT BREAK OPEN BATTERY CELL.
Other Precautions:DO NOT INCINERATE OR MUTILATE; DO NOT SHORT
CIRCUIT-MAY CAUSE BURNS.

Exposure Controls

Respiratory Protection:NIOSH APPROVED SELF-CONTAINED BREATHING
APPARATUS (IF BURNED)
Ventilation:NOT APPLICABLE.
Protective Gloves:NEOPRENE OR PVC GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EYE WASH & DELUGE SHOWER .
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
APPEAR/ODOR:CADMIUM ELECTRODE, NICKEL ELECTRODE AND KOH OR NAOH
ELECTROLYTE. EXPLAN OF CARCIN:RPT ON CARCINS, 1994:ANTIC TO BE
CARCIN. HUMAN:LUNG, PROSTATE, RENAL SYS EFTS. NICKEL:IARC
MONOGRAPHS ON E VAL OF CARCIN RISK OF CHEMS TO MAN, VOL49, PG 257,
1990:GROUP 2B. 7TH ANNUAL RPT ON CARCINS, 1994:ANTIC TO BE (ING 9)

Chemical Properties

Appearance and Odor:EACH BATTERY CELL IS A SEALED CYLINDRICAL CONTAINER
ENCLOSING A (SUPDAT)

Stability

Stability Indicator/Materials to Avoid:YES
NOT APPLICABLE.
Stability Condition to Avoid:NOT APPLICABLE.
Hazardous Decomposition Products:TOXIC FUMES MAY BE RELEASED IF
INCINERATED.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH APPLICABLE LOCAL,
STATE AND FEDERAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.